Class 100 CleanTuff tubing is a cleanroom, low density barefoot, virgin polyethylene resin blend. Cleantuff has been specifically designed for use in cleanroom packaging applications where cleanliness levels meeting or exceeding IEST-CC-STD 12460 level 100 are necessary. DegageCorp’s "CleanTuff" does not contain any additives such as slip agent, anti-blocking agent or antioxidants and "CleanTuff" exhibits excellent characteristics in the area of low ionic contamination, low out-gassing and low non-volatile residue. It does not exhibit the typical characteristics of low density barefoot polyethylene material such as blocking "CleanTuff" tubing opens extremely easily.
"CleanTuff" FILM PHYSICAL PROPERTIES | ||||
PHYSICAL PROPERTIES |
|
|||
Film Properties | ASTM Method | Units | Typical Value | |
Tensile Strength (Break) | D-882 | PSI | ||
MD | • | • | 4350 | |
TD | • | • | 4270 | |
Elongation (Break) | 0-882 | % | • | |
MD | • | • | 410 | |
TD | • | • | 675 | |
Dart Drop Impact | D1709 | Grams | 263 |
Note: All values given are based on a 1.25mil thick film
Typical values represent laboratory values and are intended as guides only, not specifications.
CleanTuff Ionic Contamination TESTING
In the chart below are listed test results showing the degree of ionic contamination for DegageCorp’s product line of class 100 or class 5 cleanroom bags, films and tubing. The anions and cations are shown as the lowest levels achievable. The ammonium, as shown in the chart, is the result of polyethylene amide groups which contain low levels of NH3 groups. It is also partly attributable to our deionizing process which releases minute particles of ammonium into the atmosphere.
The test results, done by an outside laboratory, do not reflect a cleanliness level (ie: class 100 to class 5) or a particulation size or count for a cleanliness classification, but they are indicative of the chemical makeup of any flossing, leeching, or out-gassing that could occur in the packaging of micro-contamination sensitive parts (out-gassing organics ATD• GC/MS). Our low out-gassing and low particulation levels have led many of our 'customers to claim that our bags, films and tubing are "The most consistently clean in the industry."
MATERIAL SAFETY DATA SHEET
DegageCorp . 002 MIL CLEAR NYLON BAGS, TUBING AND FILM.
Composition/Information on Ingredients
BALAZS
|
|||
Analyte |
Reporting Limit (ug/Cm2) |
Sample 1 CleanTuff | Sample 2 A/S Poly CleanTuff |
Bromide | 0.001 | • | • |
Chloride | 0.002 | • | • |
Fluoride | 0.002 | • | • |
Nitrate | 0.002 | • | • |
Nitric | 0.002 | • | • |
Phosphate | 0.002 | • | • |
Sulfate | 0.001 | • | • |
Ammonium | 0.0001 | 0.001 | 0.032 |
Potassium | 0.007 | • | • |
Sodium | 0.007 | • | • |
INGREDIENT NAME | CAS# | Weight % |
Polycaprolactam (Non hazardous) | 25038-54-4 | Proprietary |
Trace impurities and additional material names not listed above may also appear in the Regulatory Information section towards the end of the MSDS. These materials may be listed for local "Right to Know" compliance and for other reasons.
HAZARDS IDENTIFICATION:
EMERGENCY OVERVIEW: A clear or colored plastic film. Not considered hazardous under normal usage. Can release irritating and/or toxic vapors if involved in a fire.
POTENTIAL HEALTH HAZARDS:
SKIN: Not considered hazardous.
EYES: Not considered hazardous. May cause mechanical irritation if film comes into contact with the eye.
INHALATION: Not a route of exposure under normal usage. Elevated processing temperatures may release irritating vapors.
INGESTION: NOT a route of exposure. Not considered hazardous.
DELAYED EFFECTS: None known
ENGINEERING CONTROLS: General room ventilation plus local exhaust at points of fume generation to maintain exposure below the PEL/TLV exposure limits.
PERSONAL PROTECTIVE EQUIPMENT:
SKIN PROTECTION: Not normally required. Use heat resistant gloves if handling melted material.
EYE PROTECTION: As a general practice in manufacturing areas, safety glasses that conform to ANSI Z87.1 should' be worn.
RESPIRATORY PROTECTION: Under normal usage, not normally required. A NIOSH/MSHA approved respirator should be worn in areas where the PEL/TLV is exceeded.
ADDITIONAL RECOMMENDATIONS: None
EXPOSURE GUIDELINES:
INGREDIENT NAME | ACGIH TLV | OSHA PEL |
TW A = 20mg/m3 STEL = 40mg/m3 |
** = Workplace Environmental Exposure Level (AlHA).
*** = Biological Exposure Index (ACGIB).
OTHER EXPOSURE LI~UTS FOR POTENTIAL DECOMPOSITION PRODUCTS: None
PHYSICAL AND CHEMICAL PROPERTIES
PHYSICAL STATE | Solid |
ODOR | None |
SPECIFIC GRAVITY (Water = 1.0) | 1.05-1.25 |
SOLUBILITY IN WATER <"Weight %) | Negligible |
pH | Not applicable |
BOILING POINT | Not applicable |
MELTING POINT | 220-223°C (428-433°F) |
VAPOR PRESSURE | Negligible at room temperature |
VAPOR DENSITY (Air = 1.0) | Not determined |
EVAPORATION RATE | Not applicable |
COMPARED TO | Not applicable |
% VOLATILES | Negligible |
FLASH POINT | > 400°C |
STABILITY AND REACTIVITY:
NORMALLY STABLE (CONDITIONS TO AVOID): Normally stable, Avoid exposure to open flame or temperatures exceeding recommended processing temperatures.
Incompatibilities: Strong oxidizing agents, acids, and bases.
HAZARDOUS DECOMPOSITION PRODUCTS: Thermal decomposition products may include: caprolactam, carbon monoxide, carbon dioxide, hydrogen Cyanide, and ammonia when exposed to extreme heat.
HAZARDOUS Polymerization: Will not occur.
TOXICOLOGICAL INFORMAITON:
IMMEDIATE (ACUTE) EFFECTS: Not determined.
DELAYED (SUBCHRONIC &CHRONIC) EFFECTS: None known
ECOLIGICAL INFORMATION: Material is considered inert and not expected to be biodegradable or toxic.
DISPOSAL CONSIDERATIONS: Not Applicable
RCRA: Is the unused product a RCRA hazardous waste if discarded? No
If yes, the RCRA ID number is:
OTHER DISPOSAL CONSIDERATIONS:
Dispose of in compliance with Federal, state and local government regulations. Usually considered an inert package material that can be recycled-or land filled.The information offered here is for the products shipped. Use an/or alterations to the product such as mixing with other materials may significantly change the characteristics of the material and alter the RCRA classification and proper disposal method.
TRANSPORT INFORMATION:
US DOT HAZZARD CLASS: Not regulated
US DOT ID#: Not applicable
REGULATORY INFORMATION:
TOXIC SUBSTANCES CONTROL ACT (TSCA)
TSCA INVENTORY STATUS: All components used to produce the above formulations-are listed on the TSCA Inventory.
OTHER TSCA issues: None
SARA TITLE IU/CERCLA: "Reportable Quantities"(RQs) and/or "Threshold Planning Quantities" (TPQs) exist for the following ingredients:
INGREDIENT | SARA/CERCLA RQ (lb) | SARA EHS TPO (Ib) |
No ingredients listed in this section |
Spills resulting in the loss of any ingredient at or above its RQ require immediate notification to the National Response Center (1- 800-424-8802) and. to your local emergency planning committee.
SECTION 311 HAZARD CLASS: None
SARA 313 TOXIC CHEMICALS: The following ingredients are SARA 313 "Toxic Chemicals". CAS #'s and weight percents are found under composition/information on ingredients.
INGREDIENT | COMMENT |
No ingredients listed in this section |
INGREDIENT | WT.% | COMMENT |
No ingredients listed in this section |
Additional Regulatory Information: The base monomers listed on the EINECS Inventory
WHM'S CLASSIFICATION (CANADA): Not a controlled substance. (Considered to be a manufactured article)
For other information, contact Degage Corp. (972) 524 - 2979 (Monday-Friday, 9:00am-5:00pm - central standard time) It is your responsibility to determine that our product is safe, lawful, and technically suitable for your intended uses. This material safety data sheet cannot cover all possible situations which the user may experience during processing. Each aspect of the user’s operation should be examined to determine if, or where, additional precautions may be necessary. All health and safety information contained in this material safety data sheet should be provided to employees and/or customers. Degage Corp must rely on the user to use this information to develop appropriate work practice guidelines and employee instructional programs specific to the user’s operation. As the conditions and methods of use are beyond our control, we do not assume any responsibility and expressly disclaim any liability for any use of these products. Information contained herein is believed to be true and accurate, but all statements or suggestions are made without warranty, expressed, or implied, regarding accuracy of the information, the hazards connected with the use of the material or the results to be obtained from the use thereof. Compliance with all applicable international, federal, state, and local laws and regulations regarding the use, storage, sale, transport or disposal of this material is the responsibility of the user. Degage Corp. does not endorse or claim suitability of its product for any particular use. Degage Corp. MAKES NO WARRANTY OF MERCHANTABILITY AS TO ITS LDPE RESINS. Degage Corp. MAKES NO WARRANTIES, EXPRESS OR IMPLIED, CONCERNING THE SUITABILITY OR FITNESS OF ANY Degage Corp. PRODUCT FOR ANY PARTICULAR USE. Degage Corp's liability and your exclusive remedy for any claim arising out of the sales of its products are expressly limited at Degage Corp's option to replacement of non-performing goods or payment not to exceed the purchase price plus transportation charges thereon in respect to any material which damage is proven and claimed. The information in this MSDS is valid for cited regulations published as of the date this document was prepared, as shown on page 1. Updates may be prepared as the regulations are amended or pending revised information about the resin. It is the customer’s responsibility to seek updated regulatory information on any specific resin.